Wednesday, 26 February 2014

A few words about the innovation center and my experience


It has been a great opportunity for me to work at the Srujana center for Innovation at L V Prasad Eye Institute (LVPEI) in Hyderabad. I came to know about this center as I came in touch with some amazing doctors at LVPEI through the "DIy: Engineering the Eye" innovation workshop conducted with the Camera Culture Group at MIT-Media Lab and a few others organizations in July 2013 at BITS Pilani Hyderabad where students, researchers and professionals from engineering, medical and design background brainstormed and rapid-prototyped breakthrough ideas for eye care.

I’m a recent electrical and electronics engineering graduate and I joined this center as a Research Associate. My project here is about making electrophysiological testing more accessible and affordable – which is something which well complements my learning interests as well as the interests of this center. 

LVPEI being a leading center for eye care is very resourceful in terms of access to expert medical professionals and abundance of patients. The center is well equipped with tools and supplies which has been important for me to quickly test and implement ideas. I greatly appreciate that my mentors have been always reachable for guidance and assistance of any kind in their busy schedule. It has been a few months as of writing this and the development of my project has been fast-paced which is quite awesome. I feel fortunate that I’m at right place to turn innovative ideas to solutions.

Update 1


Hi all,

I’m here to give a quick update that has been pending for a while. I must warn that you won’t see too many numbers, figures and detailed description in this blog and that’s intentional.

I spent first few weeks solidifying device concept to support applications that include patient monitoring, diagnostics, research experiments and body-computer interfaces (BCI). Enabling all of these in a single device may seem a bit overwhelming but it’s certainly achievable by implementing commonalities of all the possible applications in hardware and the specifics of each application in software. A key aspect of the system is having a well-thought hardware and software stack. 

Due to the inherent modularity in our approach all possible applications need not be developed to make the device usable. So for the limited time I have I would develop applications which would involve ECG, EOG, ERG and possibly EEG.

What’s done...

-          Developed hardware architecture featuring:
o   High quality recording of data from biopotential amplifiers
o   Support for I/O devices (stimulus/user-controls) with latency calibration and intensity adjustments.
o   Scalability for multielectrode systems like EEG, and newly evolved technologies like multielectrode ERG (meERG)
-          Got a qualitative sense of requirements in terms of resolution of magnitude (bit depth), time-resolution (sampling rate) and time-accuracy (latencies) by reviewing literature on equipment used in electrophysiology.
-          Got quantitative sense of the requirements by going through hundreds of electronic component specification sheets and application notes to see what’s feasible with latest electronic devices. I ordered a few components and started working on the biopotential amplifier design.
-         Most existing biopotential amplifiers have poor noise performance because they have a number of analog stages to process the signals. I'm working on an alternative technique that uses fewer stages and takes advantage of advances in noise performance of recent analog frond end ICs, boasting theoretical noise performance far exceeding most of the existing designs. The concept took many iterations of the designing, testing and tweaking cycle to give validating results. This has been the most time consuming block so far.

What's up currently...

In the recent MIT Media Lab Health Technology workshop at IIT-Bombay I had an opportunity to discuss my designs with Bruce Hecht an engineer at Analog Devices Inc. who has worked on ICs for ECG frontends. He understood my challenges and gave some useful tips from his experience which has helped me with my circuit designs.

The circuit design that I’ve finalized has given me good results in lab. I was able to see my EOG clearly without any filtering in hardware or software. The amplitude of the EOG that I tested was nearly 24uV with around 100uV of 50Hz noise. To be able to see ERG and VEP I need to start working on signal processing in software, especially to remove the 50Hz noise. My current design tolerates DC offset up to +/- 100mV with DC coupling and offers even more with an optional AC coupling. More components are being ordered to scale up the performance to the desired 0.1 uV resolution.

Expected timeline...

  • Build a high quality sine-wave source with 0.1uV amplitude to test the amplifier quantitatively.
  • Prepare GUI frontend to visualize signals and apply various filters – this is to test the performance of biopotential amplifiers.
  • Once the complete circuit design is validated, other functionality will be added and another set of components may be ordered.
  • A PCB design will be created. The PCBs and components will be ordered to create prototypes.
  • Development of application programming interfaces (APIs) for communication with the hardware and to form several useful modules for application services like data visualization, analysis, calibration and tests to support easy application development.
  • by May'14 some sample applications will be developed and the platform will be demonstrated.


A quick tour of the lab...
















Wednesday, 18 December 2013

Initial project proposal

I recently joined innovation center at LVPEI as a Research Associate to work on electrophysiological testing of the eye. So I'm share research proposal as given under. Please review and share your opinion.

General purpose, high-performance system for clinical electrophysiological testing based on modern computational techniques featuring low cost, extensible framework and enhanced user experience
 
Abstract — Continuous improvements in noise performance of analog frontends resulting from advancements in IC fabrication processes and growing availability of powerful computers in form of smartphones, tablets and personal computers allowing use of computational techniques such as digital signal processing and machine learning suggests a need to reconsider the approach for clinical electrophysiological testing. Performance enhancements in these systems can enhance its user experience by reducing testing time and invasiveness for a test subject. There is a substantial benefit in designing a general purpose system as most systems for electrophysiological testing have significant similarities in their operating principles, differing only in biopotential signal levels, presentation of test results, type and placement of electrodes, user interface and test specific stimulus if applicable. A general purpose system for electrophysiological testing is therefore being proposed to offer substantial functional benefits and flexibility over existing commercial systems. It will be first demonstrated for visual diagnostics in the best interest of LVP-MITRA innovation center at L V Prasad Eye Institute, Hyderabad where this research is being carried out.

A quick self-explanatory block diagram


The Electrodes, DAS/GPIO and Stimulus blocks constitute the hardware. Test definition, Digital filters, Supervised learning and UI blocks are implemented in software. Electrodes are placed suitably on a patient or test subject and a stimulus if needed as in case of ERG and VEP is set up. The clinician selects an appropriate test from the UI for which a test definition is available.

Test definition:
Test definitions are test specific algorithms that use all other subsystems as required for a specific test. This is the heart of extensibility of the design. It also includes how the result is being presented and what controls are made available in the UI when a particular test is selected.

Data acquisition and General Purpose IO (DAS/GPIO)
DAS/GPIO is a hardware component that contains the analog frontend with a dynamic range large enough (>106dB) for capturing all biopotential signals in 5mV to 0.1uV range, avoiding clipping and recovery delay. 'Most' filters will be implemented in software as digital filters have better roll-off and phase characteristics and do not add to the cost. To compensate for and measure DC offset at the inputs of the biopotential amplifier and to preserve its dynamic range, the amplifier design has auto-zeroing technique. The GPIO block is used allow test logic to exchange data with stimulus generator or interactive controls if used. To comply with safety standards it also uses digital isolators to prevent the test subject from becoming a part of the mains circuit. 

Supervised learning:
Supervised learning is a machine learning algorithm that can be used to: 
  • Identify useful features in waveforms
  • Identify and ignore invalid waveforms when taking multiple trials for applying signal averaging. This can considerably reducing testing time.
  • To provide quick screening tests based on how a normal signal looks like.
Machine learning relies on large amounts of data gained from experience, so there is a need to integrate training routines into the UI. The UI can take short surveys during each test to effortlessly train the system with normal use. Features based on machine learning will stay inactive unless the system has been sufficiently trained.